4FT 18W Emergency T8 LED Tube for Commercial Safety Lighting
4FT 18W Emergency T8 LED Tube for Commercial Safety Lighting is backordered and will ship as soon as it is back in stock.
4FT 18W Emergency T8 LED Tube for Commercial Safety Lighting is backordered and will ship as soon as it is back in stock.
Description
Description
4FT 18W Emergency T8 LED Tube for Commercial Safety Lighting
The Eco Bright Light 4FT Emergency T8 LED Tube provides bright everyday illumination and dependable battery-powered backup lighting from one integrated lamp. During normal operation, the 18W tube delivers 2,000 lumens of clear 5000K light. If utility power fails, the internal lithium-ion battery automatically supplies approximately 1,100 lumens for at least 120 minutes.
Automatic Emergency Operation
The integrated backup system automatically activates when normal AC power is interrupted.
120+ Minute Runtime
Provides approximately two hours or more of emergency illumination for exit routes and occupied areas.
High Emergency Output
Delivers approximately 1,100 lumens during battery operation for improved visibility.
Automatic Monthly Testing
An intelligent self-test function checks emergency operation and activates a fault indicator when necessary.
Technical Specifications
| Brand | Eco Bright Light |
| Product Type | Emergency T8 LED Tube with Integrated Backup Battery |
| Nominal Length | 4 Feet |
| Normal Input Power | 18W |
| Normal Lumen Output | 2,000 Lumens |
| Emergency Power | Approximately 5W-8W |
| Emergency Lumen Output | Approximately 1,100 Lumens |
| Emergency Runtime | At Least 120 Minutes |
| Charging Time | More Than 10 Hours |
| Battery Type | Integrated Polymer Lithium-Ion Battery |
| Battery Rating | 11.1V, 2Ah |
| Color Temperature | 5000K Daylight |
| Input Voltage | 100-277V AC |
| Operating Frequency | 47-63Hz |
| CRI | >80 |
| Power Factor | ≥90% |
| Total Harmonic Distortion | ≤20% |
| Nominal Light Distribution | Approximately 120° |
| Maximum Overall Length | Approximately 47.72 in / 1,212 mm |
| Tube Body Length | Approximately 47.17 in / 1,198 mm |
| Illuminated Length | Approximately 44.80 in / 1,138 mm |
| Tube Dimensions | Approximately 28.5 × 32.5 mm |
| Lens | Frosted Light-Diffusing Cover |
| LED Technology | Integrated SMD LED Chips |
| Installation Type | Direct-Wire Ballast-Bypass Installation |
| Wiring Options | Default Type-B Wiring or Type-C Wiring with Separate Switched and Emergency Feeds |
| Emergency Controls | Hidden Battery Switch and Manual Emergency Test Button |
| Status Indicators | Charging, Full Battery and Fault Status Indicators |
| Self-Test Function | Automatic Initial Test and Monthly Emergency Inspection |
| Certifications | ETL, cETL and FCC |
| Warranty | 5-Year Limited Warranty |
Reliable Emergency Lighting in One Tube
- Combines normal and emergency lighting in one four-foot LED tube.
- Automatic battery operation activates when utility power is lost.
- High emergency output improves visibility in large indoor spaces.
- Two-hour backup supports extended outages and evacuation periods.
- Integrated test button allows convenient manual function checks.
- Automatic monthly inspection reduces routine testing requirements.
- Indicator lights display charging and battery status.
- Universal-voltage input supports commercial electrical systems.
Intelligent Battery Monitoring
The built-in emergency system includes a hidden battery activation switch, manual test button and charging indicators. After initial charging, the internal program performs a short automatic function test. It also conducts a monthly emergency inspection and activates a warning indicator when abnormal battery or emergency operation is detected.
Ballast-Bypass Installation
This emergency LED tube is designed for direct line-voltage installation. Existing fluorescent starters and ballasts must be removed or fully disconnected. The default Type-B wiring configuration or Type-C configuration with separate normal and emergency conductors must follow the supplied wiring diagram.
Emergency lighting wiring must maintain the required unswitched charging supply. Installation, testing and circuit modification should be completed by a qualified electrician according to the supplied instructions and applicable electrical and life-safety codes.
Commercial Emergency Lighting Applications
Ideal for offices, warehouses, classrooms, hospitals, clinics, meeting rooms, stores, restaurants, hallways, stairwells, common areas, exit routes and other commercial or institutional spaces requiring dependable backup illumination.
4FT Emergency LED Tube | Emergency T8 Tube Light | Battery Backup LED Tube | Commercial Emergency Lighting | Office Emergency Lighting | Warehouse Safety Lighting | Hallway Emergency Lighting | Emergency Retrofit Tube | 5000K T8 LED Tube | Direct Wire LED Tube
Maintain Visibility During Unexpected Power Outages
Choose Eco Bright Light for bright 18W daily operation, 1,100-lumen emergency illumination, 120-minute battery backup and intelligent automatic testing.
Package Information
| Package Size | 48.5 × 1.5 × 1.5 in |
| Pack Quantity | 1 Tube |
| Package Weight | 1.21 lbs |
Payment & Security