The Eco Bright Light Red LED Exit Sign Combo combines illuminated exit identification and emergency area lighting in one compact commercial fixture. Bright red EXIT illumination provides clear egress guidance, while two adjustable LED emergency heads direct light toward corridors, stairways, doors and other critical exit routes. The built-in rechargeable battery provides more than 90 minutes of emergency operation during an AC power failure.
Bright Red EXIT Display
Twelve red LEDs provide clear, easy-to-recognize EXIT illumination for commercial and institutional egress applications.
90+ Minute Battery Backup
The integrated rechargeable battery maintains EXIT visibility and emergency lighting for more than 90 minutes during a power outage.
Two Adjustable LED Heads
Aim the emergency heads toward doorways, hallways, stairways and other required egress areas.
Single or Double Face
Configure the fixture for one-way or two-way viewing according to the installation position and exit route.
Technical Specifications
| Brand | Eco Bright Light |
| Product Type | Red LED Emergency Exit Sign Combo |
| Input Power | 5W |
| Input Voltage | 120V / 277V AC |
| Input Current | Approximately 0.04A |
| Efficiency / Power Factor | Approximately 0.86P |
| EXIT Display Color | Red |
| EXIT Sign LEDs | 12 Red LEDs |
| Emergency Light Heads | Two Adjustable LED Heads |
| Listed Emergency Output | 1W-2W |
| Emergency Runtime | More Than 90 Minutes |
| Recharge Time | Approximately 24 Hours |
| Battery Type | Integrated Rechargeable Lead-Acid Battery |
| Battery Rating | 3.6V / 800mAh |
| Face Configuration | Single- or Double-Face Installation |
| Directional Arrows | Removable Left and Right Chevron Arrows |
| Housing Material | White Flame-Retardant Thermoplastic |
| Test Function | Integrated Manual Test Button |
| Status Indicator | Integrated Charge Indicator |
| Central Housing Width | Approximately 11.73 in |
| Overall Dimensions | Approximately 16.93 × 7.36 × 1.77 in |
| Mounting Options | Wall Mount or Ceiling Mount |
| 120V Connection | Black Line Lead and White Neutral Lead |
| 277V Connection | Red Line Lead and White Neutral Lead |
| Ground Connection | Green Ground Lead |
| Location Use | Indoor Use Only |
| Outdoor Use | Not Approved for Outdoor Installation |
| Safety Listing | UL 924 Listed |
Reliable Red EXIT Identification and Emergency Lighting
- Combines illuminated exit identification and emergency lighting in one fixture.
- Bright red EXIT illumination provides clear egress identification.
- Single- or double-face installation supports multiple viewing directions.
- Removable arrows provide left, right or arrowless exit direction.
- Two adjustable LED heads provide targeted emergency illumination.
- Battery backup operates for more than 90 minutes during AC power loss.
- 120V and 277V dual-voltage input supports commercial electrical systems.
- Flame-retardant thermoplastic housing provides lightweight, durable construction.
Configurable Exit Direction and Visibility
Configure the Red LED Exit Sign Combo for single-face or double-face visibility according to the installation position. Removable left and right chevron arrows allow exit direction to be configured for left-facing, right-facing or arrowless applications based on the building layout.
This product version is configured with a red EXIT display. Confirm the required face configuration, arrow direction and mounting method before installation or bulk ordering.
Adjustable Emergency Light Coverage
Two adjustable LED emergency heads allow light to be directed toward exit doors, hallways, stairways, corridor intersections and other critical egress areas. Adjust each head after installation to improve emergency illumination based on the mounting position and building layout.
90+ Minute Emergency Battery Backup
During normal operation, the internal rechargeable battery remains charged and ready for emergency use. If utility power is interrupted, the battery powers the red EXIT display and emergency light heads for more than 90 minutes, helping maintain exit visibility and emergency illumination during power outages.
Wall or Ceiling Installation
Install the fixture on a compatible electrical junction box using the designated mounting pattern for wall or ceiling installation. For 120V service, connect the black line conductor and white neutral conductor. For 277V service, connect the red line conductor and white neutral conductor. Connect the green grounding conductor and securely cap the unused voltage lead.
Disconnect AC power and unplug the battery before installation or servicing. After installation, restore AC power and allow the battery to charge for at least 24 hours before performing a full emergency-duration test. Cap all unused conductors with approved wire connectors.
Installation and Safety
This fixture is intended for indoor use. Do not install outdoors or near gas or electric heaters, and do not allow the power supply cord to contact hot surfaces. Proper grounding is required where applicable. Installation and servicing should be performed by qualified personnel in accordance with applicable installation codes and ordinances.
Commercial Egress Lighting Applications
Well suited for offices, schools, retail stores, restaurants, hotels,
apartment corridors, warehouses, healthcare facilities, hallways,
stairways, exit doors and other indoor commercial or institutional
emergency exit routes.
Red LED Exit Sign | Red Exit Sign Combo |
Red Emergency Exit Sign | LED Exit Sign with Emergency Lights |
Battery Backup Exit Sign | Adjustable Emergency Light |
Dual Head Emergency Light | 90 Minute Exit Sign |
120V Exit Sign | 277V Exit Sign |
Commercial Exit Sign | Commercial Egress Lighting |
UL 924 Exit Sign
Red EXIT Guidance and Emergency Lighting in One Fixture
Choose Eco Bright Light for bright red exit identification, two adjustable emergency heads, more than 90 minutes of battery backup, 120V / 277V compatibility and flexible wall or ceiling installation.
Package Information
| Package Size | 16 × 16 × 16 in |
| Pack Quantity | 12 Fixtures |
| Package Weight | 32 lbs |
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.